V Double Pump

Short Description:

Shape and introduction These series of composition vane pumps in high performance are developed for industrial application. They can be applied properly in the hydraulic system of plastic injection machinery, rubber machinery, casting machinery, machine tool industry, etc. The main features are: 1.The designing structure of composition vanes reduces its impact on the stator, so the pumps will have further stability and longer lifetime while working with high pressure and high speed. 2.The des...


Product Detail

Product Tags

Shape and introduction
These series of composition vane pumps in high performance are developed for industrial application. They can be applied properly in the hydraulic system of
plastic injection machinery, rubber machinery, casting machinery, machine tool industry, etc.
The main features are:
1.The designing structure of composition vanes reduces its impact on the stator, so the pumps will have further stability and longer lifetime while working with high pressure and high speed.
2.The designing structure of composition vanes itself reduces the noise. The design of 12 vanes makes smaller flow pulsation and lower noise.
3.Multi-displacement option and the cartridge structure of pump core make flexible application and easy maintenance.
v-double-pump
Model Descriptions

(F3-)

****V

**

A

**

(F)

–**

*

22

*

Front marks

Code

of series

Displacement

Codes shaft

end pump

Pump port

connection

Displacement

Codes shaft

end pump

Mounting

type

Shaft extension

Pump

position

Designing

No.

Direction

of rotation

No mark:

water-in oil

emulsion of

petroleum

Series

F3:

Sul phosuccinic

ester fatty

of acid

2520V

10,12,14,

15,17,19,21

4 Bolted

flange

2,3,4,5,6,7,8,9,

10,11,12,14

No mark-flange

mounting

F-foot

mounting

1-straight

shaft with key

86-heavy-duty

straight shaft

with key

11-spline shaft

See as the

following table

22

(viewed from the

shaft end

of the pump)

L-counterclockwise

rotation

R-clockwise rotation

3520V

21,25,30,

32,35,38,45

2,3,4,5,6,7,8,9,

10,11,12,14

3525V

21,25,30,32,

35,38,45

10,12,14,15,17,19,21

4525V

42,45,50,57,

60,66,75

2,3,4,5,6,7,8,9,

10,11,12,14

4525V

42,45,50,57,

60,66,75

10,12,14,15,17,

19,21

4535V

42,45,50,57,

60,66,75

21,25,30,32,35,

38,45

The rated displacement (USgpm) is under the conditions of 1200r/min and 0.69Mpa(100psi)
Pump oil port position (viewed from cover end pump)
v-double

Pump position

All series(except for 4535V)

4535V

The first outlet is

the opposition

side of inlet

AA

The second outlet is to counterclockwise rotation of 135°from inlet

The second outlet is the opposition side of inlet

AB

The second outlet is to counterclockwise rotation of 45°from inlet

The second outlet is to counterclockwise rotation of 90°from inlet

AC

The second outlet is to clockwise rotation of 45°from inlet

The second outlet is the same side of inlet

AD

The second outlet is to clockwise rotation of 135°from inlet

The second outlet is to clockwise rotation of 90°from inlet

The first outlet is to counterclockwise rotation of 90°from inlet

BA

The second outlet is to counterclockwise rotation of 135°from inlet

The second outlet is the opposition side of inlet

BB

The second outlet is to counterclockwise rotation of 45°from inlet

The second outlet is to counterclockwise rotation of 90°from inlet

BC

The second outlet is to clockwise rotation of 45°from inlet

The second outlet is the same side of inlet

BD

The second outlet is to clockwise rotation of 135°from inlet

The second outlet is to clockwise rotation of 90°from inlet

The first outlet is the same side of inlet

CA

The second outlet is to counterclockwise rotation of 135°from inlet

The second outlet is the opposition side of inlet

CB

The second outlet is to counterclockwise rotation of 45°from inlet

The second outlet is to counterclockwise rotation of 90°from inlet

CC

The second outlet is to clockwise rotation of 45°from inlet

The second outlet is the same side of inlet

CD

The second outlet is to clockwise rotation of 135°from inlet

The second outlet is to clockwise rotation of 90°from inlet

The first outlet is to clockwise rotation of 90°from inlet

DA

The second outlet is to clockwise rotation of 135°from inlet

The second outlet is the same side of inlet

DB

The second outlet is to counterclockwise rotation of 45°from inlet

The second outlet is to counterclockwise rotation of 90°from inlet

DC

The second outlet is to clockwise rotation of 45°from inlet

The second outlet is the same side of inlet

DD

The second outlet is to counterclockwise rotation of 135°from inlet

The second outlet is to clockwise rotation of 90°from inlet

Installation Sizes
v-double-installation

Models

Φa×all screw holes, 4 holes

Φb×all screw holes, 4 holes

Φc×all screw holes, 4 holes

2520V

1/2-13UNC-2B×23.8  depth

3/8-16UNC-2B×20.1  depth

3/8-15UNC-2B×20.1  depth

3520V

5/8-11UNC-2B×25.4  depth

7/16-14UNC-2B×21.0 depth

3/8-15UNC-2B×20.1  depth

3525V

5/8-11UNC-2B×25.4  depth

7/16-14UNC-2B×21.0 depth

3/8-15UNC-2B×20.1  depth

4520V

5/8-11UNC-2B×25.4  depth

1/2-13UNC-2B×23.8  depth

3/8-15UNC-2B×20.1  depth

4525V

5/8-11UNC-2B×25.4  depth

1/2-13UNC-2B×23.8  depth

3/8-15UNC-2B×20.1  depth

 

Models

A

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

2520V

50.8

26.2

12.7

25.4

52.4

101-6/101.5

9.53

63.5

88.9

19.1

14.2

75.2

88.1

101.6

38.1

3520V

62

30.1

15.9

31.7

58.7

127/126.9

9.53

76.2

106.3

19.1

17.5

75.2

99.6

114.3

38.1

3525V

62

30.1

15.9

31.7

58.7

127/126.9

9.53

76.2

106.3

25.4

17.5

74.7

109.5

114.3

38.1

4520V

69.9

35.7

15.9

38.1

69.9

127/126.9

12.7

88.9

120.6

19.1

17.5

75.2

120

119.4

42.9

4525V

69.9

35.7

15.9

38.1

69.9

127/126.9

12.7

88.9

120.6

25.4

17.5

74.7

136

119.4

42.9

 

Models

R

S

T

U

V

W

X

Y

Z

2520V

76.2

250

85.3

146.1

120

14

174.7

22.2

47.6

3520V

82.6

273.3

88.9

181

148

16

213

22.2

47.6

3525V

82.6

287.3

88.9

181

148

16

213

26.2

52.4

4520V

93.7

303.5

102.4

181

148

16

213

22.2

47.6

4525V

93.7

325

102.4

181

148

16

213

26.2

52.4

Installation Sizes
v-double-installation1
Operation and Maintenance

1.Hydraulic oil
It is recommended to adopt anti-wear hydraulic fluids with viscosity of with viscosity of 32cst-68cst under the temperature of 40°C,or automobile crankcase oil with alphabetic marks of SC, SD,SE or SF. The recommended viscosity under rated rotation speed and rated pressure should range from 13cst to 54cst with the temperature range of 49℃ to 65℃.
2. Cold start
In the case of adopting SAE 10W type hydraulic oil with viscosity between 860cst and 54cst, the operating rotation speed and pressure shall be limited within 50% of rated rotation speed and rated pressure respectively, until the system warms up. Particular attention should be paid to make sure that the whole system including the cylinder and motor on the far away side shall be all warmed up, when the pump starts up with the hydraulic oil viscosity exceeding 860cst.
3. High temperature operation
While working under high temperature, the viscosity shall not be less than 13cst, and the temperature shall not exceed 99℃. Otherwise, the service lifetime of pump core components and sealing parts will be reduced.
4. Noise data
The average conditions for noise value testing of series of pumps.
1. Test with rotation speed of 1500r/min in mute laboratory.
2. Anti-wear hydraulic oil with the viscosity of 30cst.
3. The testing temperature of hydraulic oil ranges from 45℃ to 50℃.
4. The distance between the noise sampling site and the back side of pump shall be one meter away.